Our stainless steel end caps and end scrolls offer a high quality brushed satin finish, the ideal choice for finishing off any handrail, offering a simple install without the need for onsite welding. Made from high quality stainless steel with a brushed 320 grit satin finish, with options available for interior and exterior applications.
Our range of connectors, allows you to join tube to tube and tube to wall at any conceivable angle. If you are installing in tight corners or on uneven surfaces our products provide a practical solution to every challenge. All of our connectors are designed to fit perfectly with our tube.
Our range of connectors, allows you to join tube to tube and tube to wall at any conceivable angle. If you are installing in tight corners or on uneven surfaces our products provide a practical solution to every challenge. All of our connectors are designed to fit perfectly with our tube.
Our stainless steel end caps and end scrolls offer a high quality brushed satin finish, the ideal choice for finishing off any handrail, offering a simple install without the need for onsite welding.
End Caps End Cap for Side Cladding (Left). Origin Flex Fit is one of the most competitively priced channel systems on the market. Its sleek profile make it particularly popular for domestic applications. Flex Fit profiles can be supplied in both 2.6m and 5m lengths helping to minimise the waste on any installation and has an anodised coating which is salt water resistant.
End Caps End Cap for Side Cladding (Right). Origin Flex Fit is one of the most competitively priced channel systems on the market. Its sleek profile make it particularly popular for domestic applications. Flex Fit profiles can be supplied in both 2.6m and 5m lengths helping to minimise the waste on any installation and has an anodised coating which is salt water resistant.
Left end cap for Flex Fit Side Fix channel. Origin Flex Fit is one of the most competitively priced channel systems on the market. Its sleek profile make it particularly popular for domestic applications. Flex Fit profiles can be supplied in both 2.6m and 5m lengths helping to minimise the waste on any installation and has an anodised coating which is salt water resistant.
Right end cap for Flex Fit Side Fix channel. Origin Flex Fit is one of the most competitively priced channel systems on the market. Its sleek profile make it particularly popular for domestic applications. Flex Fit profiles can be supplied in both 2.6m and 5m lengths helping to minimise the waste on any installation and has an anodised coating which is salt water resistant.
PLEASE NOTE: Measurement is taken from outside of profile to outside of profile.
Skyforce Top Mount according Test BS 6180 (0,74 kN/m)Tested to Aluminium
GLASS WIDTH UP TO
GLASS THICKNESS (tempered glass)
GLASS HEIGHT
1000mm
12.76mm
300mm – 1100mm
1700mm
16.76mm
300mm – 1100mm
3000mm
21.52mm
500mm – 1100mm
(According test BS 6180)
Tested on the basis that the minimum thickness of the aluminium frame is 1.4mm.
FIXING TO PVC FRAMESkyForce Top Mount Tested to Plastic According to the German Standard ETB Directive
GLASS WIDTH UP TO
GLASS THICKNESS (tempered glass)
GLASS HEIGHT
1600mm
12.76mm
700mm-1200mm
2100mm
16.76mm (17.52)
900mm-1200mm
2600mm
21.52mm
800mm-1100mm
Tested on the basis that the metal insert in the frame is a minimum of 1.5mm in thickness. I attach a copy of the test report which is in German but which I think we can include anyway.
FIXING TO STEEL OR CONCRETE
Skyforce is fully tested at a height of 1.1m up to a width of 3m when fixed to steel or concrete.
Glass
H = Glass Height
L = Glass Length
Working Line Load
6.62
min. 300mm - max. 1100mm
max. 1100mm
3.0 kN/m
6.62
min. 500mm - max. 1100mm
max. 1100mm
3.0 kN/m
8.84
min. 300mm < 500mm
max. 1100mm
3.0 kN/m
8.84
min. 500mm - max. 1100mm
max. 1100mm
3.0 kN/m
8.84
min. 600mm - max. 1100mm
max. 1700mm
1.5 kN/m
8.84
min. 300mm < 600mm
max. 1700mm
0.74 kN/m
10.10.4
min. 300mm < 500mm
max. 500mm
3.0 kN/m
10.10.4
min. 500mm - max. 1100mm
max. 1100mm
3.0 kN/m
10.10.4
1100mm
max. 3000mm
0.74 kN/m
10.10.4
min. 300mm < 1100mm
max. 3000mm
0.36 kN/m
FIXED TO TIMBER OR STONE/BRICKWORK
No test data available.
For more comprehensive test data, click here