Glass Windbreak in Bolton Bolton, the largest town in Britain located in the North West of England is home to about 260,000 people, one of which our next case study is about.  When this customer approached us wanting a glass windbreak in their garden we were delighted to help. The customer wanted a glass panels
Glass Balustrade Wind Breaker in Leicester

Glass Balustrade Wind Breaker in Leicester

Glass Balustrade Wind Breaker in Leicester Often when thinking of a balustrade, especially a one made of glass, people think of the aesthetic look of the system allowing for the uninterrupted views it can provide from a balcony or patio. Also they have other uses like in this project, as a wind break. This customer
We use cookies to improve your experience on our website. By browsing this website, you agree to our use of cookies.

PLEASE NOTE: Measurement is taken from outside of profile to outside of profile.

Skyforce Top Mount according Test BS 6180 (0,74 kN/m)Tested to Aluminium
GLASS WIDTH UP TO GLASS THICKNESS (tempered glass) GLASS HEIGHT
1000mm 12.76mm 300mm – 1100mm
1700mm 16.76mm 300mm – 1100mm
3000mm 21.52mm 500mm – 1100mm
(According test BS 6180) Tested on the basis that the minimum thickness of the aluminium frame is 1.4mm.   FIXING TO PVC FRAME SkyForce Top Mount Tested to Plastic According to the German Standard ETB Directive
GLASS WIDTH UP TO GLASS THICKNESS (tempered glass) GLASS HEIGHT
1600mm 12.76mm 700mm-1200mm
2100mm 16.76mm (17.52) 900mm-1200mm
2600mm 21.52mm 800mm-1100mm
Tested on the basis that the metal insert in the frame is a minimum of 1.5mm in thickness. I attach a copy of the test report which is in German but which I think we can include anyway.   FIXING TO STEEL OR CONCRETE Skyforce is fully tested at a height of 1.1m up to a width of 3m when fixed to steel or concrete.
Glass H = Glass Height L = Glass Length Working Line Load
6.62 min. 300mm - max. 1100mm max. 1100mm 3.0 kN/m
6.62 min. 500mm - max. 1100mm max. 1100mm 3.0 kN/m
8.84 min. 300mm < 500mm max. 1100mm 3.0 kN/m
8.84 min. 500mm - max. 1100mm max. 1100mm 3.0 kN/m
8.84 min. 600mm - max. 1100mm max. 1700mm 1.5 kN/m
8.84 min. 300mm < 600mm max. 1700mm 0.74 kN/m
10.10.4 min. 300mm < 500mm max. 500mm 3.0 kN/m
10.10.4 min. 500mm - max. 1100mm max. 1100mm 3.0 kN/m
10.10.4 1100mm max. 3000mm 0.74 kN/m
10.10.4 min. 300mm < 1100mm max. 3000mm 0.36 kN/m
FIXED TO TIMBER OR STONE/BRICKWORK   No test data available.   For more comprehensive test data, click here